|
1 - Contactors
Across the line
contactors..............................................................
Section 1.1–1.136
[back to top]
| 4 pole, A9 - A/AE75 |
1.13 |
| 4 pole, AF45 - AF75 |
1.14 |
| 4 pole, AL9 - AL26 |
1.13 |
| 4 pole, EK110 - EK1000 |
1.13 |
| A/AE9 - A/AE110 Contactors
for ring tongue termination |
1.10 |
| A/AF/AL & AE Auxiliary
contact blocks |
1.16 |
| A9 - A/AE75, 4 pole |
1.13 |
| A9 - A110 Interlocks for
two horizontally mounted contactors |
1.17 |
| A9 - A300 General
information |
1.2 |
| A9 - A300, Non-reversing,
mechanically interlocked, reversing |
1.3 |
| A9 - AF1650, Features |
1.1 |
| A9 - AF1650, NEMA rated,
Non-reversing, mechanically interlocked, reversing |
1.11 |
| A95 - AF750 Interlocks for
two horizontally mounted contactors |
1.17 |
| A95 - AF750 Interlocks for
two vertically mounted contactors |
1.17 |
| Accessories |
1.16 - 1.35 |
| Accessory combinations for
A contactors |
1.18 |
| Additional terminal blocks
for A/AE/AL/AF contactors |
1.29 |
| AE9 - AE110, General
information |
1.4 |
| AE9 - AE110,
Non-reversing, mechanically interlocked, reversing |
1.5 |
| AE9 - AF1650, NEMA rated,
Non-reversing, mechanically interlocked, reversing |
1.12 |
| AF1350 - AF1650 Interlocks
for two horizontally mounted contactors |
1.17 |
| AF45 - AF75, 4 pole |
1.14 |
| AF50 - AF1650, General
information |
1.8 |
| AF50 - AF1650,
Non-reversing, mechanically interlocked, reversing |
1.9 |
| AL9 - AL26, 4 pole |
1.13 |
| AL9 - AL26, NEMA rated,
Non-reversing, mechanically interlocked, reversing |
1.12 |
| AL9 - AL40 General
information |
1.6 |
| AL9 - AL40, Non-reversing,
mechanically interlocked, reversing |
1.7 |
| AL9Z - AL16Z,
Non-reversing, mechanically interlocked, reversing |
1.7 |
| Arc chutes for A/AE/AL/AF
contactors |
1.29 |
| Auxiliary contact block
technical data, CA5/CAL5-11/CAL18-11/CC5 |
1.19 |
| Auxiliary contact block
technical data, CE5 |
1.20 |
| Auxiliary contact blocks,
A/AF/AL & AE |
1.16 |
| Auxiliary lead terminals |
1.17 |
| CA5/CAL5-11/CAL18-11/CC5
Auxiliary contact block technical data |
1.19 |
| Capacitor switching, 3
phase, UA26 - UA110 |
1.15 |
| CE5 Auxiliary contact
block technical data |
1.20 |
| Coils & coil voltage codes
for A/AE/AL/AF contactors |
1.26 |
| Coils & coil voltage codes for EK
contactors |
1.27 |
| Connection kits for phase
to phase for A/AE/AL/AF contactors |
1.28 |
| Connection kits for
reversing for A/AE/AL/AF contactors |
1.28 |
| Connection kits for
wye-delta
starters for A/AE/AL/AF contactors |
1.28 |
| Contact kits for
A/AE/AL/AF contactors |
1.25 |
| Dimensions, approximate,
across the line contactors |
1.83 - 1.96 |
| EK110 - EK1000, 4 pole |
1.13 |
| Electronic timer, TE5S, for
wye-delta
starters |
1.31 - 1.32 |
| Features, A9 - AF1650 |
1.1 |
| General information, A9 -
A300 |
1.2 |
| General information, AE9 -
AE110 |
1.4 |
| General information, AF50
- AF1650 |
1.8 |
| General information, AL9 -
AL40 |
1.6 |
| Horizontal connection bars between contactor and MCCB
for A/AE/AF contactors |
1.30 |
| Identification markers for
A/AE/AL/AF contactors |
1.25 |
| Interface relays for A
contactors |
1.23 - 1.24 |
| Interlocks for two
horizontally mounted contactors, A9 - A110 |
1.17 |
| Interlocks for two
horizontally mounted contactors, A95 - AF750 |
1.17 |
| Interlocks for two
horizontally mounted contactors, AF1350 - AF1650 |
1.17 |
| Interlocks for two
vertically mounted contactors, A95 - AF750 |
1.17 |
| Mechanical latches for
A/AE/AL/AF contactors |
1.25 |
| Mechanically interlocked,
A9 - A300 |
1.3 |
| Mechanically interlocked,
AE9 - AE110 |
1.5 |
| Mechanically interlocked,
AE9 - AF1650, NEMA rated |
1.12 |
| Mechanically interlocked,
AF50 - AF1650 |
1.9 |
| Mechanically interlocked, AL9 - AL26, NEMA
rated |
1.12 |
| Mechanically interlocked,
AL9 - AL40 |
1.7 |
| Mechanically interlocked,
AL9Z - AL16Z |
1.7 |
| Mechanically interlocked, NEMA
rated, A9 - AF1650 |
1.11 |
| NEMA rated, A9 - AF1650,
Non-reversing, mechanically interlocked, reversing |
1.11 |
| NEMA rated, AE9 - AF1650, Non-reversing, mechanicallly
interlocked, reversing |
1.12 |
| NEMA rated, AL9 - AL26, Non-reversing, mechanicallly
interlocked, reversing |
1.12 |
| Non-reversing, A9 - A300 |
1.3 |
| Non-reversing, AE9 - AE110 |
1.5 |
| Non-reversing, AE9 - AF1650, NEMA
rated |
1.12 |
| Non-reversing, AF50 -
AF1650 |
1.9 |
| Non-reversing, AL9 - AL26, NEMA
rated |
1.12 |
| Non-reversing, AL9 - AL40 |
1.7 |
| Non-reversing, AL9Z -
AL16Z |
1.7 |
| Non-reversing, NEMA rated,
A9 - AF1650 |
1.11 |
| Pneumatic timers |
1.17 |
| Possible accessory
combinations for A contactors |
1.18 |
| Relays, interface, for A
contactors |
1.23 - 1.24 |
| Reversing, A9 - A300 |
1.3 |
| Reversing, AE9 - AE110 |
1.5 |
| Reversing, AE9 - AF1650, NEMA
rated |
1.12 |
| Reversing, AF50 - AF1650 |
1.9 |
| Reversing, AL9 - AL26, NEMA
rated |
1.12 |
| Reversing, AL9 - AL40 |
1.7 |
| Reversing, AL9Z - AL16Z |
1.7 |
| Reversing, NEMA rated, A9
- AF1650 |
1.11 |
| Ring tongue termination,
A/AE9 - A/AE110 |
1.10 |
| Shorting bars for A/AE/AF
contactors |
1.30 |
| Surge suppressors for
A/AE/AL/EK
contactors |
1.21 - 1.22 |
| Technical data for TE5S Electronic timer for
wye-delta
starters |
1.32 |
| Technical data, Auxiliary
contact blocks, CA5/CAL5-11/CAL18-11/CC5 |
1.19 |
| Technical data, Auxiliary
contact blocks, CE5 |
1.20 |
| Technical data,
IEC,
contactors |
1.41 - 1.82 |
| Technical data, Interface
relays |
1.24 |
| Technical data, UL & CSA,
contactors |
1.36 - 1.40 |
| Terminal blocks,
additional, for A/AE/AL/AF contactors |
1.29 |
| Terminal enlargements for
A/AE/AL/AF contactors |
1.29 |
| Terminal extensions for
A/AE/AL/AF contactors |
1.29 |
| Terminal lug kits for
A/AE/AL/AF contactors |
1.25 |
| Terminal marking and
positioning for AE/AL contactors |
1.35 |
| Terminal markings & positioning for
A/UA
contactors |
1.34 |
| Terminal markings for
CA/CC/CAL/CCL
auxiliary contacts |
1.33 |
| Terminal shrouds for
A/AE/AL/AF contactors |
1.29 |
| Terminals, auxiliary lead |
1.17 |
| Timer, electronic, TE5S, for
wye-delta
starters |
1.31 - 1.32 |
| Timers, pneumatic |
1.17 |
| UA26 - UA110 for 3 phase
capacitor switching |
1.15 |
| Vertical connection bars between contactor and MCCB
for A/AE/AF contactors |
1.30 |
Definite purpose
contactors.........................................................
Section 1.97-1.104
[back to top]
Drive contactors
............................................................................
Section 1.105-1.114
[back to top]
Lighting contactors
...................................................................... Section
1.115-1.120
[back to top]
Welding contactors
......................................................................
Section 1.121-1.126
[back to top]
AC Switching contactors
............................................................ Section
1.127-1.130
[back to top]
2 - Overload relays
Thermal overload
relays
..................................................................... Section
2.1-2.18
[back to top]
DC Switching contactors
............................................................ Section
1.131-1.134
[back to top]
Bar contactors
...............................................................................
Section 1.135-1.136
[back to top]
Electronic overload relays
............................................................... Section
2.19-2.28
[back to top]
3 - Starters
General
information .............................................................................
Section 3.1-3.10
[back to top]
Across the line starters
.................................................................... Section
3.11-3.46
[back to top]
Combination starters
........................................................................ Section
3.47-3.70
[back to top]
| Additional auxiliary
contact blocks |
3.49 |
| Catalog number explanation |
3.48 |
| Circuit breaker type, non-reversing, NEMA
rated |
3.58 - 3.59 |
| Circuit breaker type,
reversing |
3.60 - 3.61 |
| Circuit breaker type, reversing, NEMA
rated |
3.62 - 3.63 |
| Control circuit
transformer |
3.49 |
| Control cover accessories |
3.49 |
| Description |
3.47 |
| Dimensions |
3.64 - 3.70 |
| Disconnect switch type,
fusible, non-reversing |
3.52 - 3.53 |
| Disconnect switch type,
fusible, reversing |
3.54 - 3.55 |
| Disconnect switch type,
non-fusible |
3.50 - 3.51 |
| Factory modifications |
3.49 |
| Fusible disconnect switch
type, non-reversing |
3.52 - 3.53 |
| Fusible disconnect switch
type, reversing |
3.54 - 3.55 |
| Hazardous location
enclosure accessories |
3.49 |
| Non-fusible disconnect
switch type |
3.50 - 3.51 |
| Overload relay protection |
3.47 |
| Price adders for reduced
voltage & multi-speed starters |
3.49 |
| Special modifications |
3.49 |
Reduced voltage starters
................................................................ Section
3.71-3.92
[back to top]
4 - Miniature controls
Miniature
controls ................................................................................
Section 4.1-4.20
[back to top]
5 - Manual motor protectors
Manual
motor protectors
.................................................................... Section
5.1-5.28
[back to top]
6 - Softstarters
Type PSS
Softstarters
........................................................................ Section
6.1-6.20
[back to top]
Type PST Softstarters
...................................................................... Section
6.21-6.50
[back to top]
|